Cuerpo de escaneado Astra
video

Cuerpo de escaneado Astra

Introducción a la producción astra scanbody es un tipo de materiales dentales CAD CAM para soluciones de implantes orales. Puede ser adecuado para diferentes sistemas como MIS,Osstem,Dentium,BIOMET,Astra,Ankylos,Ankylos Friadent Xive, NobelBoicare Active,Nobelbiocare Replace,Nobelbiocare Branemark,Straumann Bone...
Envíeconsulta

Descripción

Parámetros técnicos

Introducción a la producción

cuerpo de escaneo astra is one kind of Dental CAD CAM Materials for oral implant solution. It can be suitable for different system like MIS,Osstem,Dentium,BIOMET,Astra,Ankylos,Ankylos Friadent Xive,
NobelBoicare Active,Nobelbiocare Replace,Nobelbiocare Branemark,Straumann Bone Level,Zimmer, Lifecore, Camlog and Kyocera etc.

 

astra scanbody is also digital solution components for dental implant system, which is made of Ti or Ti alloy with Peek, and it's usage for dental transfer scanning. The package can be customized according to market request.

 

Las precauciones de uso del cuerpo de escaneado:

The problem that the scanbody is difficult to scan, the most important thing is to expose the characteristic surface, like a metal scan body, its surface is easy to image after sandblasting, so how can we ensure that the characteristic surface faces to the buccal side? Or the lingual side, preferably to the buccal side, because the buccal side is easier to scan and image, then let's take a look, the bottom of scan body is actually a hexagonal screw, the hexagonal shape means it can be rotated at any free, when placing the scan body on the healing abutment, tighten the screws. Be careful to tighten them gently. The screw is just in place. At this time, it is best to take an X-ray film, and then scan. Sometimes we will encounter with two implants that are very close. If we turn the characteristic surface of the scanbody towards the buccal side, the mesial and distal parts of the characteristic surface are all exposed clearly. After put it in position, pull out the screwdriver. The 2 features face the buccal side, which is easy to scan, It mainly need to place the scanbody in right place. And the scanning process become more easier and fast.


The Effects of Scanbody Delamination

Usually, Each implant company will have a corresponding scanbody database for data matching, and each scan body has a corresponding characteristic surface and top platform. If the scan body is layered, when the data is matched in the design software, it will happen that the scan body cannot match the implant database.

 

Main Causes of Scan body Delamination

When scanning the lingual side of the scanbody, it can't scan to the top part of the scanbody, so that the position data at the junction between the top of the scanbody and the lingual side is lost when scanning the top of the scanbody, so delamination occurs.

 

Cómo solucionar los problemas de delaminación

1. If the scan body is delaminated in a small area, you can repeat scan the scan body area 2-3 times to automatically optimize it.

2. If the scanbody is delaminated in a large area, the scanbody part should be re-scanned according to the correct scanning path.

 


cuerpo de escaneo astra Foto

 

 

cuerpo de escaneo astraopciones de sistema compatibles:

 

different system

Certification 

certifications 


 

Packing  Delivery

transportation andpackage 

Perfil de la empresa

 

 

Fotos de la exposición:

exhibition 

 

 

 

Preguntas más frecuentes

P: ¿Quiénes somos?
A: We are based in Guangdong, China, start from 2008, sell to Domestic Market(50.00 percent ),North America(20.00 percent ),South America(10.00 percent ),Eastern Asia(5.00 percent ),Western Europe(5.00 percent ),Eastern Europe(3.00 percent ),Mid East(3.00 percent ),Northern Europe(2.00 percent ),Southern Europe(2.00 percent ). There are total about 51-100 people in our office.

 

P: ¿ES USTED EMPRESA COMERCIAL O FABRICANTE?

R: Somos fabricantes con más de 15 años de experiencia en el campo de soluciones digitales de implantes dentales.

vuelo al aeropuerto internacional de Baoan. Bienvenido a nuestra fábrica para visitar.

P: ¿PROPORCIONAN MUESTRAS GRATIS?

R: podemos proporcionar la muestra y debemos cobrar la tarifa de la muestra. La tarifa de muestra se devolverá cuando se realice el pedido en masa

 

P: ¿Pueden hacer un certificado de origen (C/O) y un certificado de calidad?

R: Sí. Si se solicita, el certificado de origen y el certificado de calidad se pueden proporcionar cuando se envían las mercancías.

 

P: ¿CUÁNTO ES EL TIEMPO DE ENTREGA?

R: normalmente, tarda de 3 a 7 días, el tiempo de entrega para pedidos grandes debe verificarse cuando se realiza el pedido.

 

Q: Why choose the dental implant solution from Chirimen?

A: For full range of optimized and digitalized dental treatment solutions, we introduced world-class biological surface treatment technology, implant production line and detection equipment, and clean workshop is in line with the national GMP standard. Under the background of Chirimen's over 15 years' medical device quality control system and over 10 years' dental implant RD. Our own quality management system was established combining the international leading-edge management resources.

 


Etiqueta: scanbody astra, China, proveedores, fabricantes, fábrica, venta al por mayor, compra, precio, en venta, hecho en China

Envíeconsulta